Categories:

PFA insulated thermocouple wire, type K, solid wire, 2×1/30AWG,  PFA insulated, PFA sheathed thermocouple extension cable. Standardtolerances and ANSI color code.

Additional information

Color

Conform to internetional color standard

Size

8-36AWG

MOQ

200m

Package

By rool / spool

Discover more about PFA Thermocouple Wire K-30-PFA

1. Introduction:
Thermocouple Extension cable is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.

2. Construction: 
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass              (ambient temperature range 0-300ºC
PVC                       (ambient temperature range 0-105ºC)
Telflon                  (ambient temperature range 0-350ºC)
Silicone rubber   (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, teflon, silicone rubber
Galvanized layer: stainless steel, tinned brass

3.Standard: conforms to IEC584 standard.

4. Color Code:Table 1
Kapton Insulated Thermocouple Wire K Type 36 AWG

PFA Thermocouple Wire K-30-PFA

Description:

1, SUBJECT
PFA insulated thermocouple wire, type K, solid wire, 2×1/30AWG,  PFA insulated, PFA sheathed thermocouple extension cable.

Standardtolerances and ANSI color code.

2, TECHNICAL FEATURES

SL NO SPECIFICATIONS
K-TYPE THERMOCOUPLE WIRE
Description Of Item K-Type Thermocouple Wire
1 -Thermocouple type K-type(Nicro-Nial)
2 -color combination as per ANSI/BS/JIS and equivalent standard
3 -Wire type Single-strand(each conductor)
4 -Wire size 30 AWG gauge for each conductor
5 -Insulation Extruded type Teflon insulation over single wire
6 -Configuration stranded
7 -Accuracy Special grade(±0.5 deg C) as per ANSI/BS/JIS and equivalent standards
8 -Range of temperature measurement 260◦C

5. How to select:Order Code: e.g.

J 2*7/0.3 FG FG SS DIN

1                           2                                                 3                         4                          5                       6

1  Thermocouple Types: K, J, E, T, N, S          RTD: Cu, Ni

2  Conductot dimension:
2*7/0.3 means 2 cores,  each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)

3 Insulated layer materials:
FG: fiberglass   PVC: PVC      TF: teflon        SR: silicone rubber

4 Jacket layer material
FG: fiberglass   PVC: PVC      TF: teflon        SR: silicone rubber

5 Galvanized Layer material:   SS: stainless steel  TB: tinned brass

6Color Code:
ANSI: American standard   DIN: Germany standard    BS:Britain standard
NFC: France Standard          JIS: Japan Standard           IEC: IEC standard

    Add a header to begin generating the table of contents
    Scroll to Top

    Related Products

    EnglishSpanishPortugueseChinese (Simplified)

    Ask For a Quick Quote

    We will contact you within 1 working day, please pay attention to the email with the suffix “@ht-elite.com”