Thermocouple Extension wire Type J-FG/FG/-2×7/20AWG.
Color Standard | Conform to internetional color standard |
---|---|
Size | 8-36 AWG |
MOQ | 200m |
1. Introduction:
Thermocouple Extension wire is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.
2. Construction:
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass (ambient temperature range 0-300ºC
PVC (ambient temperature range 0-105ºC)
Telflon (ambient temperature range 0-350ºC)
Silicone rubber (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, teflon, silicone rubber
Galvanized layer: stainless steel, tinned brass
3.Standard: conforms to IEC584 standard.
4. Product Description
Thermocouple Extension wire Type J-FG/FG/-2×7/20AWG.
This specification covers the requirements for fiberglass insulated, thermocouple extension cable, 2×20AWG, stranded wire, standard tolerance and color code.
A. Conductors:
Stranded thermocouple extension wire
Conductors Size(AWG) | NO.of Strands &Gauge |
20 | 7/0.3mm |
B. Assembly:
Two conductors (positive and negative) parallel construction.
C. CALIBRATION TOLERANCE
Temperature range | Standard tolerance | Special tolerance |
0ºC to 400ºC | ±2.2ºC or 0.75% | ±1.1ºC or 0.4% |
Types Available: K, J, E, T, N, J
Constuction Available:
Constructure: fiberglass +fiberglass
Constructure: fiberglass +stainless steel braided (FG+SSB)
Constructure: fiberglass +fiberglass +stainless steel braided (FG+FG+SSB)
Constructure: fiberglass +teflon (FG+TF)
Thermocouple extension wire type available: KX, JX, TX, EX, NX, RX,SX and other compensating
cable like KCA, KCB and so on.
We will contact you within 1 working day, please pay attention to the email with the suffix “@ht-elite.com”.