Categories:

T-Type Thermocouple Wire T-FEP-28, temperature -200◦C  to +150◦C. FEP insulated thermocouple wire, type T, solid wire, 2×1/28AWG, standard tolerances and ANSI color code.

Additional information

Color

Conform to internetional color standard

Size

8-36 AWG

MOQ

300m

Package

By rool / spool

Discover more about FEP Thermocouple Wire T-FEP-28

1. Introduction:
Thermocouple Extension cable is usually used to connect thermocouple and display-controled meters in order to lower the inaccuracy caused by temperature change on the connections.

2. Construction: 
Conductor: original thermocoupole alloy material, in solid wire or strand wires
Insulation Layer:
Fiberglass              (ambient temperature range 0-300ºC
PVC                       (ambient temperature range 0-105ºC)
Telflon                  (ambient temperature range 0-350ºC)
Silicone rubber   (ambient temperature range 0-180ºC)
Jacket layer materials: fiberglass, PVC, teflon, silicone rubber
Galvanized layer: stainless steel, tinned brass

3.Standard: conforms to IEC584 standard.

4. Color Code:Table 1
Kapton Insulated Thermocouple Wire K Type 36 AWG

FEP Thermocouple Wire T-FEP-28-ANSI
Description:

1, SUBJECT
FEP insulated thermocouple wire, type T, solid wire, 2×1/28AWG, standard tolerances and ANSI color code.

2, TECHNICAL FEATURES

SL NO SPECIFICATIONS
T-TYPE THERMOCOUPLE WIRE
Description Of Item T-Type Thermocouple Wire
1 -Thermocouple type T-type(Copper-Constantan)-as per ASTM E230 and ANSI MC96.1
2 -color combination white –Blue (preferable) or as per ANSI/BS/JIS and equivalent standard
3 -Wire type Single-strand(each conductor)
4 -Wire size 28 AWG gauge for each conductor
5 -Insulation Extruded type Teflon insulation over single wire
6 -Configuration Both wires in twisted  configuration
7 -Accuracy Special grade(±0.5 deg C) as per ANSI/BS/JIS and equivalent standards
8 -Range of temperature measurement -200◦C  to +150◦C
9 -coating copper
10 -out gassing TML ≤1.0 %, CVCM ≤0.1 %

5. How to select:Order Code: e.g.

J 2*7/0.3 FG FG SS DIN

1                           2                                                 3                         4                          5                       6

1  Thermocouple Types: K, J, E, T, N, S          RTD: Cu, Ni

2  Conductot dimension:
2*7/0.3 means 2 cores,  each core includes 7 strands wire,
each wire diameter is 0.3mm, more example: 2×7/0.2, 2×4/0.65, 2×1/0.3 etc.
Other way to symbol the conductor dimensions:
Conductor square meter: 0.25mm²
AWG standard (see*Table 2)

3 Insulated layer materials:
FG: fiberglass   PVC: PVC      TF: teflon        SR: silicone rubber

4 Jacket layer material
FG: fiberglass   PVC: PVC      TF: teflon        SR: silicone rubber

5 Galvanized Layer material:   SS: stainless steel  TB: tinned brass

6Color Code:
ANSI: American standard   DIN: Germany standard    BS:Britain standard
NFC: France Standard          JIS: Japan Standard           IEC: IEC standard